PROFESSIONAL REFRIGERATION SOLUTIONS
R449A REFRIGERANT GAS
25 LB (11.3 KG) CYLINDER
High-performance, lower-GWP refrigerant for
commercial and industrial refrigeration systems.
Professional Cooling Performance
R449A is a zeotropic HFO/HFC refrigerant blend designed
for low- and medium-temperature refrigeration applications.
It is commonly selected as a lower-global-warming-potential
alternative to R404A and R507 refrigerants.
R449A can be used in approved new equipment and in
suitably converted refrigeration systems. It is frequently
used in supermarkets, commercial refrigeration units,
cold storage facilities, food processing operations,
and industrial cooling applications.
With zero ozone depletion potential, ASHRAE A1 safety
classification, and a significantly lower GWP than R404A,
R449A provides an established option for compatible
commercial refrigeration equipment.
25 LB
Net Weight
A1
Safety Class
ZERO
Ozone Depletion
01 / Technical Specifications
| Refrigerant |
R449A / R-449A |
| Refrigerant Type |
HFO/HFC Zeotropic Blend |
| Composition |
R32 / R125 / R1234yf / R134a |
| Blend Percentage |
24.3% / 24.7% / 25.3% / 25.7% |
| Net Weight |
25 LB / 11.3 KG |
| Molecular Weight |
87.2 g/mol |
| Boiling Point |
Approximately -46°C |
| Liquid Density at 21.1°C |
1113.3 kg/m³ |
| Critical Temperature |
81.5°C |
| Critical Pressure |
4.45 MPa absolute |
| GWP (AR4) |
1397 |
| Ozone Depletion Potential |
0 |
| ASHRAE Safety Class |
A1 — Lower Toxicity, No Flame Propagation |
| Temperature Glide |
Approximately 4 K |
| Primary Applications |
Low- and medium-temperature refrigeration |
02 / Cylinder Features & Benefits
Pressure-Resistant Construction
A properly rated refrigerant cylinder supports handling,
transportation and storage of R449A under approved conditions.
Protective Outer Packaging
Suitable protective packaging helps reduce surface damage
during movement, warehousing and shipping.
25 LB Net Refrigerant Capacity
A practical cylinder quantity for professional servicing
and maintenance of compatible refrigeration systems.
Protected Valve Assembly
Cylinder valve and protective-collar features help support
secure storage and professional handling when provided
by the supplier.
Professional Refrigeration Applications
R449A is suitable for approved refrigeration equipment
that requires this specific refrigerant.
03 / Recommended Applications
01 — Commercial Refrigeration
Designed for compatible commercial refrigeration equipment
including supermarket display cases, refrigerated cabinets,
walk-in coolers and freezers.
02 — Equipment Retrofit
R449A is commonly used in appropriately converted R404A
and R507 refrigeration systems. Retrofit work must follow
equipment manufacturer and refrigerant supplier guidance.
03 — Food Processing
Suitable for approved food processing refrigeration
systems requiring controlled low- and medium-temperature
operation.
04 — Cold Chain Storage
Used in compatible cold rooms, refrigerated warehouses
and temperature-controlled storage facilities.
05 — Industrial Refrigeration
Applicable to approved industrial direct-expansion
refrigeration systems and other compatible installations.
04 / Professional Refrigeration Use
R449A is frequently selected by refrigeration professionals
for compatible new equipment and properly planned retrofits
of existing R404A or R507 systems.
Technicians should verify refrigeration system compatibility,
lubricant requirements, operating pressures, expansion
devices, temperature glide and manufacturer recommendations.
As a zeotropic blend, R449A should generally be charged
from the cylinder in its liquid phase, using proper methods
to avoid compressor damage and maintain the intended
refrigerant composition.
It is not a universal drop-in replacement. Conversion
may require system adjustments and must be carried out
by appropriately qualified technicians.
Safety & EPA Compliance
R449A has an ASHRAE A1 safety classification, but it is
still a pressurized refrigerant that requires controlled
handling, safe storage and proper servicing procedures.
- Use only in compatible approved refrigeration equipment.
- Keep cylinders in cool, dry, ventilated areas.
- Secure cylinders against tipping and physical damage.
- Avoid excessive heat and high temperatures.
- Follow the manufacturer's Safety Data Sheet.
- Use suitable refrigerant recovery and charging equipment.
- Do not intentionally release refrigerant into the atmosphere.
- Follow applicable EPA and local regulations.
Purchaser Notice: Buyers must meet applicable EPA
refrigerant purchasing requirements, including technician
certification or permitted resale conditions.
05 / Frequently Asked Questions
What is R449A refrigerant?
R449A is a lower-GWP HFO/HFC blend commonly used in
low- and medium-temperature commercial refrigeration.
Can R449A replace R404A or R507?
R449A can replace R404A or R507 in many compatible systems
after a properly planned retrofit. System verification
and manufacturer guidance are essential.
Is R449A flammable?
R449A has an A1 safety classification, indicating
lower toxicity and no flame propagation under the
specified standard test conditions.
What equipment uses R449A?
Compatible supermarket refrigeration systems,
walk-in coolers, commercial freezers, refrigerated
display cases and cold storage installations.
How should R449A be charged?
R449A is a zeotropic blend and should generally
be charged in the liquid phase using approved
service procedures and appropriate equipment.
Who can purchase R449A?
Purchasers must comply with applicable EPA
certification, resale and refrigerant handling regulations.
How should R449A cylinders be stored?
Store upright and secured in a cool, dry,
well-ventilated location, away from excessive heat
and physical damage.
R449A REFRIGERANT GAS
25 LB | 11.3 KG
Professional Refrigerant for Compatible
Commercial & Industrial Cooling Systems