PROFESSIONAL REFRIGERATION SOLUTIONS
R448A REFRIGERANT GAS
25 LB (11.3 KG) CYLINDER
High-performance, reduced-GWP refrigerant for compatible commercial and industrial refrigeration systems.
Professional Cooling Performance
R448A, also known commercially as Solstice N40, is a nonflammable zeotropic HFO/HFC refrigerant blend designed for low- and medium-temperature commercial refrigeration applications.
R448A offers a lower global warming potential compared with R404A while supporting efficient performance in approved refrigeration equipment. It is commonly used in supermarkets, refrigerated display cases, cold storage warehouses, commercial freezers, and approved refrigeration retrofits.
With zero ozone depletion potential and an ASHRAE A1 safety classification, R448A is an established refrigerant for compatible professional refrigeration systems.
25 LB
Net Weight
A1
Safety Class
0 ODP
Ozone Depletion
01 / Technical Specifications
| Refrigerant |
R448A / R-448A |
| Type |
Zeotropic HFO/HFC Blend |
| Composition |
R32 / R125 / R134a / R1234yf / R1234ze(E) |
| Blend Ratio |
26% / 26% / 21% / 20% / 7% |
| Net Weight |
25 lb / 11.3 kg |
| Molecular Weight |
86.3 g/mol |
| Boiling Point |
Approximately -45.9°C |
| Critical Temperature |
83.7°C |
| Critical Pressure |
4.66 MPa absolute |
| Liquid Density at 25°C |
Approximately 1092 kg/m³ |
| GWP (AR4) |
1387 |
| ODP |
0 |
| Safety Classification |
A1 — Nonflammable |
| Temperature Glide |
Approximately 7°F (3.9°C) |
| Applications |
Low- and medium-temperature refrigeration |
02 / Cylinder Features & Benefits
Pressure-Resistant Cylinder
Designed for proper containment, transport and professional handling of R448A refrigerant under approved conditions.
Protective Outer Packaging
Suitable corrugated packaging can help protect the cylinder against surface damage during transportation and storage.
25 LB Net Refrigerant Capacity
A practical quantity for qualified refrigeration professionals servicing compatible commercial systems.
Valve Protection
Approved cylinder valve assemblies and protective components support secure professional handling.
Reliable Refrigeration Applications
Suitable for equipment specifically approved for R448A refrigerant.
03 / Recommended Applications
01 — Commercial Refrigeration
For compatible supermarket refrigeration systems, refrigerated display cases, commercial freezers and walk-in coolers.
02 — Cold Chain Logistics
Used in approved refrigeration systems supporting temperature-controlled storage and distribution of perishable goods.
03 — Industrial Cooling Systems
Suitable for certain compatible industrial direct-expansion refrigeration equipment operating at low and medium temperatures.
04 — Refrigeration Retrofits
R448A can replace R404A or R507 in many compatible systems following a properly planned conversion and manufacturer-approved retrofit procedure.
05 — Food Storage & Processing
Used in suitable refrigerated warehouses, cold rooms and food-processing refrigeration systems.
04 / Professional Refrigeration Use
R448A is designed for compatible low- and medium-temperature commercial refrigeration systems. It may be used in approved new installations or properly converted existing equipment.
Professional technicians should confirm system compatibility, lubricant requirements, compressor discharge temperature, operating pressure, expansion devices and refrigerant temperature glide.
As a zeotropic refrigerant blend, R448A should generally be charged in the liquid phase using approved procedures to maintain its intended composition.
R448A must not be treated as a universal drop-in replacement. Retrofitting requires technical evaluation and may require equipment adjustments.
Safety & EPA Compliance
R448A is classified as ASHRAE A1, indicating lower toxicity and no flame propagation under specified test conditions. Pressurized refrigerant cylinders still require proper handling and storage.
- Use only in compatible approved refrigeration equipment.
- Store cylinders in a cool, dry and ventilated location.
- Keep cylinders away from excessive heat.
- Secure cylinders against tipping and physical damage.
- Follow the Safety Data Sheet and cylinder instructions.
- Use suitable recovery and charging equipment.
- Never intentionally vent refrigerant to the atmosphere.
- Comply with applicable EPA, federal, state and local regulations.
Purchaser Notice: Purchasers must satisfy applicable refrigerant sales requirements, including EPA technician certification or qualifying resale conditions.
05 / Frequently Asked Questions
What is R448A refrigerant?R448A is a nonflammable zeotropic HFO/HFC blend intended primarily for low- and medium-temperature commercial refrigeration applications.
Can R448A replace R404A?R448A can replace R404A in many compatible systems after manufacturer-approved evaluation and retrofit procedures. It is not a universal drop-in replacement.
Can R448A replace R507?It may be used in certain R507 systems following an appropriate compatibility assessment and properly executed retrofit.
Is R448A flammable?R448A has an ASHRAE A1 nonflammable safety classification under standard test conditions.
Which systems commonly use R448A?Commercial freezers, refrigerated display cases, supermarket refrigeration, cold storage and approved industrial refrigeration systems.
How should R448A be charged?As a zeotropic blend, R448A should generally be charged in the liquid phase with appropriate equipment and approved service procedures.
Is R448A environmentally friendly?R448A has zero ozone depletion potential and significantly lower GWP than R404A. However, it remains a greenhouse gas and must be managed responsibly.
Who can purchase R448A?Customers must meet applicable EPA refrigerant purchase requirements, including appropriate certification or qualifying resale conditions.
R448A REFRIGERANT GAS
25 LB | 11.3 KG
Professional Refrigerant for Compatible Commercial & Industrial Cooling Systems