{"product_id":"rtcooling-r410a","title":"R410A","description":"\n\u003cdiv style=\"max-width:100%;font-family:Arial,Helvetica,sans-serif;color:#222;line-height:1.75;overflow:hidden;\"\u003e\n\n\u003c!-- PREMIUM HEADER --\u003e\n\u003cdiv style=\"background:#111111;padding:32px 22px;border-radius:14px;text-align:center;border-bottom:6px solid #ff7900;\"\u003e\n\u003cp style=\"font-size:12px;letter-spacing:2px;color:#ff9900;font-weight:800;margin:0;\"\u003ePROFESSIONAL HVAC REFRIGERANT\u003c\/p\u003e\n\u003ch2 style=\"font-size:30px;color:#fff;margin:12px 0;\"\u003eR410A REFRIGERANT GAS\u003c\/h2\u003e\n\u003cp style=\"font-size:20px;color:#ffb15c;font-weight:bold;\"\u003e25 LB (11.3 KG) CYLINDER\u003c\/p\u003e\n\u003cp style=\"font-size:15px;color:#eee;\"\u003eHigh-pressure HFC refrigerant for professional servicing of compatible air conditioning, heat pump and HVAC systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- PRODUCT IMAGE --\u003e\n\u003cimg src=\"https:\/\/refrigerantwell.com\/cdn\/shop\/files\/1_1_a13089d9-d4f5-4c9a-a15b-15cbbc822b1e.png?v=1775978347\u0026amp;width=1946\" alt=\"R410A 25 LB refrigerant cylinder reference product\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;object-fit:contain;border-radius:12px;margin:22px 0;\"\u003e\n\n\u003c!-- OVERVIEW --\u003e\n\u003ch2 style=\"font-size:24px;color:#111;\"\u003eProfessional Air Conditioning Performance\u003c\/h2\u003e\n\n\u003cp\u003eR410A (R-410A) is a near-azeotropic HFC refrigerant blend consisting of R32 and R125 in equal proportions. Developed for high-pressure air conditioning and heat pump equipment, it became widely used in residential and light commercial HVAC applications.\u003c\/p\u003e\n\n\u003cp\u003eR410A delivers efficient cooling performance in systems specifically engineered for its operating pressures. It is commonly found in existing central air conditioners, split systems, heat pumps, and selected commercial cooling equipment.\u003c\/p\u003e\n\n\u003cp\u003eR410A has zero ozone depletion potential and an ASHRAE A1 safety classification. However, its relatively high global warming potential means new-equipment use is subject to EPA restrictions. It remains important for permitted servicing of compatible existing HVAC systems.\u003c\/p\u003e\n\n\u003c!-- HIGHLIGHTS --\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0;\"\u003e\n\u003cdiv style=\"flex:1;min-width:90px;text-align:center;background:#fff0df;border:1px solid #ffd0a0;padding:14px 8px;border-radius:9px;\"\u003e\n\u003cb style=\"font-size:18px;\"\u003e25 LB\u003c\/b\u003e\n\u003cdiv style=\"font-size:12px;\"\u003eNet Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1;min-width:90px;text-align:center;background:#fff0df;border:1px solid #ffd0a0;padding:14px 8px;border-radius:9px;\"\u003e\n\u003cb style=\"font-size:18px;\"\u003eA1\u003c\/b\u003e\n\u003cdiv style=\"font-size:12px;\"\u003eSafety Class\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1;min-width:90px;text-align:center;background:#fff0df;border:1px solid #ffd0a0;padding:14px 8px;border-radius:9px;\"\u003e\n\u003cb style=\"font-size:18px;\"\u003e0 ODP\u003c\/b\u003e\n\u003cdiv style=\"font-size:12px;\"\u003eOzone Depletion\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2 style=\"background:#ff7900;color:#fff;padding:15px 18px;border-radius:8px;font-size:21px;\"\u003e01 \/ Technical Specifications\u003c\/h2\u003e\n\n\u003cdiv style=\"background:#111;border-radius:12px;padding:24px 16px;text-align:center;margin:20px 0;\"\u003e\n\u003cdiv style=\"font-size:36px;font-weight:800;color:#ff9900;\"\u003eR410A\u003c\/div\u003e\n\u003cp style=\"font-size:14px;color:#fff;\"\u003eNEAR-AZEOTROPIC HFC BLEND\u003c\/p\u003e\n\u003cdiv style=\"display:flex;justify-content:center;gap:10px;flex-wrap:wrap;margin:15px 0;\"\u003e\n\u003cspan style=\"background:#ff7900;color:#fff;padding:9px 16px;border-radius:7px;\"\u003eR32 — 50%\u003c\/span\u003e\n\u003cspan style=\"background:#ff7900;color:#fff;padding:9px 16px;border-radius:7px;\"\u003eR125 — 50%\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp style=\"color:#ddd;font-size:13px;\"\u003e50\/50 composition by weight\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;margin:18px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff0df;\"\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eRefrigerant\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eR410A \/ R-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eChemical Components\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eDifluoromethane \/ Pentafluoroethane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff0df;\"\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eComposition\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eR32 \/ R125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eBlend Ratio\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e50% \/ 50% by weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff0df;\"\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eRefrigerant Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eNear-Azeotropic HFC Blend\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eNet Weight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e25 LB \/ 11.3 KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff0df;\"\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eMolecular Weight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e72.6 g\/mol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eNormal Boiling Point\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eApproximately -51.7°C \/ -61°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff0df;\"\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eLiquid Density at 25°C\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eApproximately 1062 kg\/m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eCritical Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eApproximately 71.4–72.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff0df;\"\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eCritical Pressure\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eApproximately 4.9 MPa absolute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eSafety Classification\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eASHRAE A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff0df;\"\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eGWP (AR4)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e2088\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eOzone Depletion Potential\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff0df;\"\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eTypical Lubricant\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003ePOE Oil — Per Equipment Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eCompatible A\/C Systems, Heat Pumps, HVAC Servicing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- FEATURES --\u003e\n\u003ch2 style=\"background:#111;color:#ff9900;padding:15px 18px;border-left:6px solid #ff7900;border-radius:8px;margin-top:30px;font-size:21px;\"\u003e02 \/ Cylinder Features \u0026amp; Benefits\u003c\/h2\u003e\n\n\u003cimg src=\"https:\/\/refrigerantwell.com\/cdn\/shop\/files\/062ea0fba34839c68dfae419d88c9507.png?v=1774887579\u0026amp;width=1200\" alt=\"R410A reference cylinder valve packaging and protective features\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;border-radius:12px;margin:18px 0;\"\u003e\n\n\u003cdiv style=\"background:#fff5e9;border-left:5px solid #ff7900;border-radius:10px;padding:20px;\"\u003e\n\u003cp\u003e\u003cb\u003ePressure-Resistant Construction\u003c\/b\u003e\u003cbr\u003eProperly rated refrigerant cylinders support safe containment, transportation and storage when handled according to cylinder manufacturer instructions.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eProtective Outer Packaging\u003c\/b\u003e\u003cbr\u003eAppropriate protective packaging helps reduce scratches, surface damage and handling impacts during shipment.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003e25 LB Net Refrigerant Capacity\u003c\/b\u003e\u003cbr\u003eA practical supply size for qualified HVAC technicians servicing compatible R410A air conditioning systems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eProtected Valve Assembly\u003c\/b\u003e\u003cbr\u003eProper valve guards and compatible protective features help protect cylinder connections during handling and storage.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eProfessional HVAC Applications\u003c\/b\u003e\u003cbr\u003eDesigned for servicing approved equipment that specifically requires R410A refrigerant.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2 style=\"background:#ff7900;color:#fff;padding:15px 18px;border-radius:8px;margin-top:30px;font-size:21px;\"\u003e03 \/ Recommended Applications\u003c\/h2\u003e\n\n\u003cimg src=\"https:\/\/refrigerantwell.com\/cdn\/shop\/files\/5d2e585db5819cebcdb2a4d5c2f76cdb_ec0a7578-1428-4e9e-8411-24889d5b08bd.png?v=1775974359\u0026amp;width=1200\" alt=\"R410A reference applications in air conditioning and heat pump systems\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;border-radius:12px;margin:18px 0;\"\u003e\n\n\u003cdiv style=\"padding:8px 10px;\"\u003e\n\u003ch3 style=\"color:#e86f00;\"\u003e01 — Residential Air Conditioning\u003c\/h3\u003e\n\u003cp\u003eUsed for permitted maintenance and servicing of existing residential central air conditioning systems originally designed for R410A.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#e86f00;\"\u003e02 — Heat Pump Systems\u003c\/h3\u003e\n\u003cp\u003eSuitable for compatible existing heat pumps operating with R410A refrigerant for heating and cooling applications.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#e86f00;\"\u003e03 — Commercial Air Conditioning\u003c\/h3\u003e\n\u003cp\u003eApplicable to existing compatible light commercial HVAC systems, packaged air conditioners and split systems requiring R410A.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#e86f00;\"\u003e04 — Mini-Split Systems\u003c\/h3\u003e\n\u003cp\u003eUsed in professional servicing of compatible ductless mini-split and multi-split air conditioning equipment originally designed for R410A.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#e86f00;\"\u003e05 — HVAC Maintenance\u003c\/h3\u003e\n\u003cp\u003eSuitable for qualified technicians performing approved refrigerant recovery, repair, charging and maintenance on existing R410A systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- PROFESSIONAL USE --\u003e\n\u003ch2 style=\"background:#111;color:#ff9900;padding:15px 18px;border-left:6px solid #ff7900;border-radius:8px;margin-top:30px;font-size:21px;\"\u003e04 \/ Professional HVAC Use\u003c\/h2\u003e\n\n\u003cp\u003eR410A has been widely used in air conditioning and heat pump equipment designed for its relatively high operating pressure.\u003c\/p\u003e\n\n\u003cp\u003eQualified technicians should verify the equipment nameplate, POE lubricant specifications, compressor operating pressures and approved service procedures before performing maintenance.\u003c\/p\u003e\n\n\u003cp\u003eAs a near-azeotropic refrigerant blend, R410A is generally charged in the liquid phase using appropriate professional procedures.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eCompatibility Notice:\u003c\/b\u003e R410A operates at substantially higher pressures than R22. It must never be used as a direct drop-in replacement in equipment designed exclusively for R22.\u003c\/p\u003e\n\n\u003c!-- SAFETY AND EPA --\u003e\n\u003cdiv style=\"background:#111;color:#fff;padding:25px 22px;border-radius:12px;border-top:5px solid #ff7900;margin-top:28px;\"\u003e\n\u003ch2 style=\"color:#ff9900;font-size:22px;margin-top:0;\"\u003eSafety \u0026amp; EPA Compliance\u003c\/h2\u003e\n\n\u003cp style=\"color:#eee;\"\u003eR410A is classified as ASHRAE A1, indicating lower toxicity and no flame propagation under standard testing conditions. Its elevated operating pressure and GWP require appropriate equipment, qualified service and regulatory compliance.\u003c\/p\u003e\n\n\u003cul style=\"padding-left:22px;color:#eee;\"\u003e\n\u003cli\u003eUse only in R410A-compatible approved equipment.\u003c\/li\u003e\n\u003cli\u003eNever use R410A as a direct replacement for R22.\u003c\/li\u003e\n\u003cli\u003eStore cylinders in a cool, dry and well-ventilated location.\u003c\/li\u003e\n\u003cli\u003eKeep cylinders away from excessive heat and physical damage.\u003c\/li\u003e\n\u003cli\u003eUse recovery and charging equipment rated for R410A.\u003c\/li\u003e\n\u003cli\u003eFollow the manufacturer Safety Data Sheet.\u003c\/li\u003e\n\u003cli\u003eDo not intentionally vent refrigerant into the atmosphere.\u003c\/li\u003e\n\u003cli\u003eFollow applicable EPA Section 608 requirements.\u003c\/li\u003e\n\u003cli\u003eCheck federal and state restrictions for new system installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"color:#ffbc75;font-size:13px;\"\u003e\u003cb\u003eRegulatory Notice:\u003c\/b\u003e Existing compatible systems may generally continue to be serviced during their useful life. R410A use in new residential and light commercial systems is restricted under EPA HFC technology-transition rules, subject to applicable exceptions.\u003c\/p\u003e\n\n\u003cp style=\"color:#ffbc75;font-size:13px;\"\u003e\u003cb\u003ePurchaser Notice:\u003c\/b\u003e Customers must comply with applicable refrigerant sales requirements, including technician certification or qualifying resale exceptions.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- FAQ --\u003e\n\u003ch2 style=\"background:#ff7900;color:#fff;padding:15px 18px;border-radius:8px;margin-top:30px;font-size:21px;\"\u003e05 \/ Frequently Asked Questions\u003c\/h2\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eWhat is R410A refrigerant?\u003c\/b\u003e\n\u003cp\u003eR410A is a near-azeotropic HFC blend containing 50% R32 and 50% R125, historically used in residential and commercial air conditioning systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eCan R410A replace R22?\u003c\/b\u003e\n\u003cp\u003eNo. R410A operates at significantly higher pressure than R22 and is not approved as a direct drop-in replacement for R22 equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eIs R410A flammable?\u003c\/b\u003e\n\u003cp\u003eR410A is classified as ASHRAE A1, meaning no flame propagation under specified standard test conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eWhich equipment uses R410A?\u003c\/b\u003e\n\u003cp\u003eMany existing central air conditioners, heat pumps, mini-splits and commercial HVAC systems originally designed for R410A.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eHow much refrigerant is in the cylinder?\u003c\/b\u003e\n\u003cp\u003eThis product contains 25 LB (approximately 11.3 KG) of R410A refrigerant.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eWhat oil does R410A require?\u003c\/b\u003e\n\u003cp\u003eMost R410A HVAC equipment uses POE lubricant. Always verify the exact oil requirements specified by the equipment manufacturer.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eHow should R410A be charged?\u003c\/b\u003e\n\u003cp\u003eR410A should generally be charged in the liquid phase using suitable equipment and approved service procedures.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eIs R410A still legal in the United States?\u003c\/b\u003e\n\u003cp\u003eYes, permitted servicing of existing R410A systems may continue. New system installation is subject to EPA HFC technology-transition rules and applicable exceptions.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eCan R454B be mixed with R410A?\u003c\/b\u003e\n\u003cp\u003eNo. R454B should not be mixed with R410A or used in equipment that has not been specifically approved for it.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eWho can purchase R410A?\u003c\/b\u003e\n\u003cp\u003ePurchasers must meet applicable EPA refrigerant sales requirements, including appropriate certification or qualifying resale conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- FINAL BANNER --\u003e\n\u003cdiv style=\"background:#111;padding:29px 18px;text-align:center;border-bottom:5px solid #ff7900;border-radius:12px;margin-top:28px;\"\u003e\n\u003ch2 style=\"color:#ff9900;font-size:26px;margin:0 0 10px;\"\u003eR410A REFRIGERANT GAS\u003c\/h2\u003e\n\u003cp style=\"font-size:18px;color:#fff;font-weight:bold;\"\u003e25 LB | 11.3 KG\u003c\/p\u003e\n\u003cp style=\"color:#ddd;font-size:14px;\"\u003eProfessional Refrigerant for Servicing Compatible Air Conditioning \u0026amp; Heat Pump Systems\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n","brand":"RTCOOLING","offers":[{"title":"1 Bottle","offer_id":67903068831973,"sku":"RT-R410A-1","price":99.0,"currency_code":"USD","in_stock":true},{"title":"5 Bottles","offer_id":67903068864741,"sku":"RT-R410A-5","price":450.0,"currency_code":"USD","in_stock":true},{"title":"8 Bottles","offer_id":67903068897509,"sku":"RT-R410A-8","price":750.0,"currency_code":"USD","in_stock":true},{"title":"10 Bottles","offer_id":67903068930277,"sku":"RT-R410A-10","price":850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0852\/6502\/3205\/files\/rs-r410a_17290de2-526a-4738-8bef-60a4642341da.png?v=1793185869","url":"https:\/\/ridertrust.us\/products\/rtcooling-r410a","provider":"RIDERTRUST","version":"1.0","type":"link"}