{"product_id":"rtcooling-r407a","title":"R407A","description":"\n\u003cdiv style=\"max-width:100%;font-family:Arial,Helvetica,sans-serif;color:#222;line-height:1.75;overflow:hidden;\"\u003e\n\n\u003c!-- HERO --\u003e\n\u003cdiv style=\"background:#111111;padding:32px 22px;border-radius:14px;text-align:center;border-bottom:6px solid #ff7900;\"\u003e\n\u003cp style=\"font-size:12px;letter-spacing:2px;color:#ff9900;font-weight:800;margin:0;\"\u003ePROFESSIONAL REFRIGERATION SOLUTIONS\u003c\/p\u003e\n\u003ch2 style=\"font-size:30px;color:white;margin:12px 0;\"\u003eR407A REFRIGERANT GAS\u003c\/h2\u003e\n\u003cp style=\"font-size:20px;color:#ffb15c;font-weight:bold;\"\u003e25 LB (11.3 KG) CYLINDER\u003c\/p\u003e\n\u003cp style=\"font-size:15px;color:#eee;\"\u003eProfessional HFC refrigerant for compatible commercial refrigeration, cold storage and industrial cooling equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- MAIN PRODUCT IMAGE --\u003e\n\u003cimg src=\"https:\/\/icecorerefrigerants.com\/cdn\/shop\/files\/R407A_4.png?v=1774855584\" alt=\"R407A refrigerant cylinder product reference\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;object-fit:contain;border-radius:12px;margin:22px 0;\"\u003e\n\n\u003c!-- OVERVIEW --\u003e\n\u003ch2 style=\"color:#111;font-size:24px;\"\u003eProfessional Refrigeration Performance\u003c\/h2\u003e\n\n\u003cp\u003eR407A (R-407A) is a non-ozone-depleting HFC refrigerant blend intended primarily for low- and medium-temperature commercial refrigeration systems.\u003c\/p\u003e\n\n\u003cp\u003eIt is commonly used in approved commercial refrigeration equipment and may be selected for certain retrofit applications involving systems originally designed for R22 or R404A, subject to system compatibility and manufacturer guidance.\u003c\/p\u003e\n\n\u003cp\u003eR407A provides an ASHRAE A1 safety classification, zero ozone depletion potential and reliable operating characteristics when installed in suitable equipment by qualified professionals.\u003c\/p\u003e\n\n\u003c!-- HIGHLIGHTS --\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0;\"\u003e\n\u003cdiv style=\"flex:1;min-width:90px;text-align:center;padding:14px 8px;background:#fff1e1;border:1px solid #ffd0a0;border-radius:9px;\"\u003e\n\u003cb style=\"font-size:18px;\"\u003e25 LB\u003c\/b\u003e\u003cdiv style=\"font-size:12px;\"\u003eNet Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1;min-width:90px;text-align:center;padding:14px 8px;background:#fff1e1;border:1px solid #ffd0a0;border-radius:9px;\"\u003e\n\u003cb style=\"font-size:18px;\"\u003eA1\u003c\/b\u003e\u003cdiv style=\"font-size:12px;\"\u003eSafety Class\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex:1;min-width:90px;text-align:center;padding:14px 8px;background:#fff1e1;border:1px solid #ffd0a0;border-radius:9px;\"\u003e\n\u003cb style=\"font-size:18px;\"\u003e0 ODP\u003c\/b\u003e\u003cdiv style=\"font-size:12px;\"\u003eOzone Depletion\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- TECHNICAL DATA --\u003e\n\u003ch2 style=\"background:#ff7900;color:white;padding:15px 18px;font-size:21px;border-radius:8px;\"\u003e01 \/ Technical Specifications\u003c\/h2\u003e\n\n\u003cdiv style=\"background:#111;color:#fff;border-radius:12px;padding:25px 16px;margin:20px 0;text-align:center;\"\u003e\n\u003cdiv style=\"font-size:34px;color:#ff9900;font-weight:800;\"\u003eR407A\u003c\/div\u003e\n\u003cdiv style=\"font-size:14px;color:#eee;margin:8px 0;\"\u003eHFC ZEOTROPIC REFRIGERANT BLEND\u003c\/div\u003e\n\u003cdiv style=\"display:flex;gap:8px;justify-content:center;flex-wrap:wrap;margin-top:16px;\"\u003e\n\u003cspan style=\"background:#ff7900;color:white;padding:9px 13px;border-radius:7px;\"\u003eR32 — 20%\u003c\/span\u003e\n\u003cspan style=\"background:#ff7900;color:white;padding:9px 13px;border-radius:7px;\"\u003eR125 — 40%\u003c\/span\u003e\n\u003cspan style=\"background:#ff7900;color:white;padding:9px 13px;border-radius:7px;\"\u003eR134a — 40%\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;margin:18px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff0df;\"\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eRefrigerant\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eR407A \/ R-407A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eType\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eHFC Zeotropic Blend\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff0df;\"\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eComposition\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eR32 \/ R125 \/ R134a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eBlend Ratio\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e20% \/ 40% \/ 40% by weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff0df;\"\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eNet Weight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e25 LB \/ 11.3 KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eMolecular Weight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e90.1 g\/mol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff0df;\"\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eNormal Boiling Point\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eApproximately -45.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eCritical Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eApproximately 82.8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff0df;\"\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eCritical Pressure\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eApproximately 4.54 MPa absolute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eSafety Classification\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eASHRAE A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff0df;\"\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eGWP (AR4)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e2107\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eOzone Depletion Potential\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff0df;\"\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eTypical Lubricant\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003ePOE — per equipment specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:11px;border:1px solid #ddd;\"\u003eMedium- and low-temperature refrigeration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- FEATURES --\u003e\n\u003ch2 style=\"background:#111;color:#ff9900;padding:15px 18px;border-left:6px solid #ff7900;border-radius:8px;margin-top:30px;font-size:21px;\"\u003e02 \/ Cylinder Features \u0026amp; Benefits\u003c\/h2\u003e\n\n\u003cimg src=\"https:\/\/freoncenter.com\/cdn\/shop\/files\/3.png?v=1761027295\u0026amp;width=1200\" alt=\"Example R407A refrigerant cylinder and protective packaging\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;border-radius:12px;margin:18px 0;\"\u003e\n\n\u003cdiv style=\"background:#fff5e9;border-left:5px solid #ff7900;border-radius:10px;padding:20px;\"\u003e\n\u003cp\u003e\u003cb\u003ePressure-Resistant Construction\u003c\/b\u003e\u003cbr\u003eProperly rated refrigerant cylinders support safe containment, transportation and storage under approved conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eProtective Outer Packaging\u003c\/b\u003e\u003cbr\u003eSuitable packaging provides additional protection against surface damage and handling impacts during shipment.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e25 LB Net Refrigerant Quantity\u003c\/b\u003e\u003cbr\u003eA practical supply size for qualified technicians servicing commercial refrigeration equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eProtected Valve Assembly\u003c\/b\u003e\u003cbr\u003eCompatible valve guards and protective cylinder collars help reduce damage to the valve area.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eProfessional Refrigeration Applications\u003c\/b\u003e\u003cbr\u003eDesigned for use with refrigeration equipment specifically approved for R407A.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2 style=\"background:#ff7900;color:#fff;padding:15px 18px;border-radius:8px;margin-top:30px;font-size:21px;\"\u003e03 \/ Recommended Applications\u003c\/h2\u003e\n\n\u003cdiv style=\"padding:8px 10px;\"\u003e\n\u003ch3 style=\"color:#e86f00;\"\u003e01 — Commercial Refrigeration\u003c\/h3\u003e\n\u003cp\u003eSuitable for compatible supermarket refrigeration equipment, refrigerated display cases, walk-in coolers and commercial freezer systems.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#e86f00;\"\u003e02 — Medium-Temperature Cooling\u003c\/h3\u003e\n\u003cp\u003eUsed in approved refrigeration systems designed to maintain controlled temperatures for commercial food storage and cooling.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#e86f00;\"\u003e03 — Low-Temperature Refrigeration\u003c\/h3\u003e\n\u003cp\u003eApplicable to suitable low-temperature freezers and industrial refrigeration installations designed or converted for R407A.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#e86f00;\"\u003e04 — R22 System Retrofits\u003c\/h3\u003e\n\u003cp\u003eR407A may be considered for certain R22 refrigeration systems after professional assessment of system design, lubricant compatibility and operating requirements.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#e86f00;\"\u003e05 — R404A Retrofit Applications\u003c\/h3\u003e\n\u003cp\u003eR407A may be used in selected refrigeration conversion projects where the manufacturer or qualified system designer approves its use.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- PROFESSIONAL USE --\u003e\n\u003ch2 style=\"background:#111;color:#ff9900;padding:15px 18px;border-left:6px solid #ff7900;border-radius:8px;margin-top:30px;font-size:21px;\"\u003e04 \/ Professional Refrigeration Use\u003c\/h2\u003e\n\n\u003cp\u003eR407A is intended for appropriately designed equipment and professional service applications involving low- and medium-temperature refrigeration systems.\u003c\/p\u003e\n\n\u003cp\u003eBefore installation or retrofit, technicians should verify compressor compatibility, POE lubricant requirements, expansion devices, operating temperatures, refrigerant pressures and applicable equipment recommendations.\u003c\/p\u003e\n\n\u003cp\u003eBecause R407A is a zeotropic blend, it should generally be charged in the liquid phase using appropriate service procedures to maintain refrigerant composition.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eCompatibility Notice:\u003c\/b\u003e R407A is not a universal drop-in replacement for R22 or R404A. Professional evaluation and system modifications may be required.\u003c\/p\u003e\n\n\u003c!-- SAFETY --\u003e\n\u003cdiv style=\"background:#111;color:#fff;padding:25px 22px;border-radius:12px;border-top:5px solid #ff7900;margin-top:28px;\"\u003e\n\u003ch2 style=\"color:#ff9900;font-size:22px;margin-top:0;\"\u003eSafety \u0026amp; EPA Compliance\u003c\/h2\u003e\n\n\u003cp style=\"color:#eee;\"\u003eR407A is classified as ASHRAE A1, meaning lower toxicity and no flame propagation under standard test conditions. Pressurized refrigerant cylinders still require appropriate professional handling.\u003c\/p\u003e\n\n\u003cul style=\"padding-left:22px;color:#eee;\"\u003e\n\u003cli\u003eUse only in compatible approved refrigeration systems.\u003c\/li\u003e\n\u003cli\u003eStore cylinders in a cool, dry and well-ventilated area.\u003c\/li\u003e\n\u003cli\u003eKeep away from excessive heat and physical damage.\u003c\/li\u003e\n\u003cli\u003eSecure cylinders against tipping during storage.\u003c\/li\u003e\n\u003cli\u003eUse appropriate recovery and charging equipment.\u003c\/li\u003e\n\u003cli\u003eFollow the manufacturer's Safety Data Sheet.\u003c\/li\u003e\n\u003cli\u003eDo not intentionally vent refrigerant.\u003c\/li\u003e\n\u003cli\u003eFollow EPA Section 608 and applicable regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"color:#ffbc75;font-size:13px;\"\u003e\u003cb\u003eEPA Purchaser Notice:\u003c\/b\u003e Refrigerant purchases and professional servicing must comply with applicable EPA certification and resale rules.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- FAQ --\u003e\n\u003ch2 style=\"background:#ff7900;color:white;padding:15px 18px;border-radius:8px;margin-top:30px;font-size:21px;\"\u003e05 \/ Frequently Asked Questions\u003c\/h2\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eWhat is R407A refrigerant?\u003c\/b\u003e\u003cp\u003eR407A is an HFC blend used primarily in commercial refrigeration systems operating at low and medium temperatures.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eCan R407A replace R22?\u003c\/b\u003e\u003cp\u003eR407A may be used in selected R22 refrigeration retrofit applications following professional compatibility assessment. It is not a universal direct replacement.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eCan R407A replace R404A?\u003c\/b\u003e\u003cp\u003eSome R404A systems may be suitable for conversion to R407A after a properly planned retrofit, subject to equipment and operating conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eIs R407A flammable?\u003c\/b\u003e\u003cp\u003eR407A has an ASHRAE A1 safety classification, indicating no flame propagation under specified standard test conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eHow much refrigerant is in the cylinder?\u003c\/b\u003e\u003cp\u003eThe listed product contains 25 LB (approximately 11.3 KG) of R407A refrigerant.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eHow should R407A be charged?\u003c\/b\u003e\u003cp\u003eAs a zeotropic blend, R407A should generally be charged in the liquid phase using approved refrigerant service procedures.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eWho can purchase R407A?\u003c\/b\u003e\u003cp\u003ePurchasers must comply with applicable EPA technician certification, resale and refrigerant sales requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"padding:13px 5px;border-bottom:1px solid #ddd;\"\u003e\n\u003cb\u003eHow should cylinders be stored?\u003c\/b\u003e\u003cp\u003eStore in a cool, dry, well-ventilated area, secured against damage and away from excessive heat, according to the cylinder label and SDS.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- FINAL BANNER --\u003e\n\u003cdiv style=\"background:#111;padding:29px 18px;text-align:center;border-bottom:5px solid #ff7900;border-radius:12px;margin-top:28px;\"\u003e\n\u003ch2 style=\"color:#ff9900;font-size:26px;margin:0 0 10px;\"\u003eR407A REFRIGERANT GAS\u003c\/h2\u003e\n\u003cp style=\"font-size:18px;color:#fff;font-weight:bold;\"\u003e25 LB | 11.3 KG\u003c\/p\u003e\n\u003cp style=\"color:#ddd;font-size:14px;\"\u003eProfessional Refrigerant for Compatible Commercial \u0026amp; Industrial Refrigeration Systems\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n","brand":"RTCOOLING","offers":[{"title":"1 Bottle","offer_id":67903069847781,"sku":"RT-R407A-1","price":99.0,"currency_code":"USD","in_stock":true},{"title":"5 Bottles","offer_id":67903069880549,"sku":"RT-R407A-5","price":450.0,"currency_code":"USD","in_stock":true},{"title":"8 Bottles","offer_id":67903069913317,"sku":"RT-R407A-8","price":750.0,"currency_code":"USD","in_stock":true},{"title":"10 Bottles","offer_id":67903069946085,"sku":"RT-R407A-10","price":850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0852\/6502\/3205\/files\/rs-r407a_e0b7e759-7404-417b-9611-9c61e5335b32.png?v=1793184731","url":"https:\/\/ridertrust.us\/products\/rtcooling-r407a","provider":"RIDERTRUST","version":"1.0","type":"link"}